Noise Suppression Examples in Mobile Communications
BaseBand in Cellular Phone
Cellular Phone Technical Trend
Top of Page
Noise of Power Supply Lines
Radiation Noise from the flexible PCB, which generated in baseband
ICs operate at high-speed, so high frequency and high level noise geneate. This type of noise may radiate through conducting to the flexible PCB and affect a antenna block.
Top of Page
Measurement Result
Mapping of Radiation Noise (GSM band) from the flexible PCB with the EMI tester
Top of Page
Introduction of NFM18PC Series
- smallest size in the industry (1.6x0.8mm)
- Three terminal structure with low residual (ESL)* realize large insertion loss characteristics over wide frequency range.
*Not exceeding one-tenth of Monolithic Ceramic Capacitors (two terminal).
(in: mm)
| Part Number |
Capacitance
(µF) |
Tolerance
(%) |
Insulation Resistance
(MΩ min.) |
Rlated Voltage
(VDC) |
Rated Current
(A) |
Operating
Temperature Range |
| NFM18PC104R1C3 |
0.1 |
M: ±20 |
1000 |
16 |
2 |
-55 to 125°C |
| NFM18PC224R0J3 |
0.22 |
6.3 |
| NFM18PC474R0J3 |
0.47 |
| NFM18PC105R0J3 |
1 |
500 |
4 |
-55 to 105°C |
Top of Page
Examination with production version (Power Supply Lines)
We have evaluated to improve the error rate performance using cellular phone (production version)
Top of Page
Voltage Spectrum
Comparison of Voltage Spectrum
- Without EMI Filter
- Existing capacitaor (27pF)
- Three-terminals Capacitor: NFM18PC105R0J3 (1µF)
Top of Page
Improvement of Error Rate Performance
RF level record of Error Rate exceeding 0%
Top of Page
Back to "Noise Suppression Examples"