Voltage-Current Characteristics (V-I Characteristics)
The diagram below is a V-I characteristics graph showing the change in voltage across terminals when the current passed through the thermistor is gradually increased at a constant temperature (25℃, in air). This characteristic is extremely important for understanding the self-heating of NTC thermistors.
V-I characteristics graph
First, because the self-heating of the thermistor can be largely ignored in the region where the current is small, the resistance value can be considered to be nearly constant at the ambient temperature (Region (1)). In this region, the voltage and current generally follow Ohm’s law (V = IR), and the voltage increases in proportion to the current increase.
However, when the current is further increased, Joule heating (I2R) inside the thermistor can no longer be ignored, and the element temperature increases (Region (2)). Since the resistance value of an NTC thermistor decreases as the temperature increases, the resistance drops at the same time as the current increases, and the increase in voltage gradually slows down. Before long, the voltage reaches the maximum value (peak). In regions after this point, a positive feedback loop of temperature increase due to self-heating → resistance decrease → current increase becomes dominant, and the voltage, on the other hand, decreases (Region (3)). This region is called the “thermal runaway region” where stable operation is not guaranteed.
In the region that exceeds the voltage peak, the thermistor exceeds the allowable temperature. Since this may lead to characteristic degradation or destruction, it cannot be used in practical applications. For this reason, it is necessary in temperature measurement applications to design circuits so that they operate within the Ohm’s law region (low-current Region (1)) where self-heating is sufficiently small.
Thermal Dissipation Constant (δ)
The thermal dissipation constant (δ) is an indicator that represents the power required to raise the element temperature by 1℃ when the thermistor self-heats. The unit is generally indicated in mW/℃ (or W/℃). A larger δ means that “heat tends to escape and the temperature does not readily increase,” while a smaller δ means that “heat tends to build up and the temperature easily increases.”
When current is passed through a thermistor, power is consumed as Joule heat as shown in the equation below.
When the element temperature increases by ΔT above the ambient temperature due to this self-heating, the thermal dissipation constant δ is defined by the following equation.
This equation shows the power P required to raise the temperature by 1℃ when ΔT = 1℃. In other words, even for the same power P, the temperature increase ΔT becomes larger in an environment with a small δ, and the measurement error (self-heating error) increases. Furthermore, the thermal dissipation constant δ is not a fixed value specific to the material. Since it is determined by the balance between the self-heating from power consumption and heat dissipation to the surroundings, the constant varies significantly depending on the operating environment and mounting conditions.
Thermal dissipation constant explanatory diagram
As shown in [Reference 1] of the “Thermal dissipation constant explanatory diagram” above, when the surroundings are spatially enclosed or the structure and layout makes it difficult for heat to escape, heat dissipation is impeded and δ becomes smaller. As a result, the temperature tends to increase even with a small amount of power, which makes errors due to self-heating more likely to occur. On the other hand, increasing the land size or wiring to make it easier for heat to escape to the board side or tweaking the material, structure, and thickness of the board as listed in [Reference 2] promotes heat dissipation and δ becomes larger. Furthermore, contact with a heat sink, the resin coating, surrounding environment, and cooling systems also impact heat dissipation, which causes δ to significantly change.
In this way, the thermal dissipation constant δ is an important parameter that is directly linked to the temperature increase due to self-heating, namely measurement error. Therefore, when using a thermistor as a temperature sensor, it is essential to estimate δ by considering the mounting conditions and surrounding environment and to design the applied current and voltage-dividing resistance value so that the self-heating stays within the allowable range.
Thermal Time Constant (τ)
The thermal time constant (τ) refers to the time required for the thermistor temperature to reach 63.2% of the final amount of temperature change when a thermistor at temperature T0 is instantly placed in an environment with an ambient temperature T1. This thermal time constant is an important indicator that represents the response speed of the thermistor.
The temperature response of a thermistor is generally expressed by the following equation as the temperature T(t) at time t.
If we set t=τ here, we get the following equation.
We can see that the time required to reach 63.2% of the temperature difference is τ.
The diagram below shows that point for the change from the initial temperature T0 to the final temperature T1, as expressed in the following equation.
The horizontal axis (time) at that moment is the thermal time constant τ.
When τ is small, the response is fast, and the resistance change of the thermistor quickly tracks the ambient temperature change. On the other hand, when τ is large, the response is slow, and the tracking of temperature changes becomes slower.
The thermal time constant τ is determined by the thermal capacity of the thermistor element, heat transfer conditions with the surrounding environment, and the mounting method, etc. Therefore, the value of τ changes, even for the same thermistor, if the operating environment or mounting conditions vary. In applications where you wish to rapidly detect temperature changes, you must select a small τ thermistor and mounting method.
Diagram showing the temperature change of a thermistor in response to changes in the ambient temperature
Maximum Voltage (Vmax)
The maximum voltage (Vmax) refers to the maximum voltage which does not cause self-heating, characteristic degradation, or destruction even if it is continuously applied to the thermistor. Since a thermistor is a resistor, applying a voltage causes a current to flow, which generates Joule heat (self-heating). Vmax is the safety limit set so that this self-heating stays within the allowable range.
The “Maximum voltage derating characteristics diagram” below shows an example of the maximum voltage derating characteristics for the NCU15 series of thermistors for general-purpose applications. The horizontal axis shows the temperature, and the vertical axis shows the maximum allowable voltage.
Maximum voltage derating characteristics diagram
With model number XH103 from the same series shown in the diagram, it is possible to apply a voltage up to a maximum of 5V in the temperature range of 100℃ or less. However, when the temperature exceeds 100℃, the maximum voltage suddenly drops, and it decreases to almost 0V around 125℃. This is because the thermistor resistance drops significantly as the temperature becomes higher, and the flowing current increases even when the same voltage is applied. As a result, power consumption increases and excessive self-heating tends to occur, making it necessary to limit the voltage that can be applied.
For this reason, the key point is to always check the Vmax characteristics within the operating temperature range when incorporating a thermistor into a circuit and design the circuit with a lower applied voltage or voltage-dividing resistance value in high-temperature environments. Usage that exceeds Vmax must be avoided, because there is a risk that it may lead not only to increased measurement errors but also to characteristic degradation or damage.
Maximum Operating Current (Iop) and Maximum Operating Voltage (Vop)
The maximum operating current (Iop) and maximum operating voltage (Vop) are the maximum operating upper limits specified by Murata Manufacturing as the conditions under which the temperature increase due to self-heating stays within 0.1℃ when a current or voltage is applied to the thermistor.
Since self-heating directly connects to measurement errors in temperature sensor applications, Iop and Vop are positioned not as “safety limits” but as recommended upper limits to ensure measurement accuracy. These values are determined by the thermal dissipation constant (δ). The temperature increase ΔT due to self-heating is expressed with the following equation.
At Murata Manufacturing, we use ΔT = 0.1℃ as the standard, calculate the allowable power consumption P from that, and then define Iop and Vop as the results.
The “Diagram of changes in maximum operating current/voltage due to differences in the thermal dissipation constant” below shows how the maximum operating current and voltage change due to differences in the thermal dissipation constant. The red lines show the results calculated at P = 1mW. The solid line shows the maximum operating voltage (Vop), and the dotted line indicates the maximum operating current (Iop). When the thermal dissipation constant is small, a temperature increase occurs even with a small amount of power, which limits Iop and Vop to low values.
Diagram of changes in maximum operating current/voltage due to differences in the thermal dissipation constant
On the other hand, the blue lines show the maximum operating current and voltage when P = 3.5mW. Since the thermal dissipation constant is 3.5 times larger under this condition compared to P = 1 mW, the maximum operating current and maximum operating voltage also become higher. In this way, the thermal dissipation constant changes depending on the operating environment (in air, board mounting, in water, wind presence, etc.) even for the same thermistor, and the maximum operating current and maximum operating voltage also change accordingly. Therefore, when determining the voltage-dividing resistance value or the applied voltage, it is necessary to ensure a sufficient margin that accounts for the thermal dissipation constant.